T-N2-HP

The F-DGSi Tower High Purity (HP) Nitrogen Generators are engineered to transform standard compressed air in to a safe regulated supply of 99.9995% pure nitrogen.
With an optional catalyst, other trace impurities such as hydrocarbons and CO are removed to levels <0.05 ppm. An additional filter is installed to remove particulates down to 0.5 microns.

The touch screen LCD interface provides simple and user friendly management of all functions on the unit.
  • Advantages
  • Characteristics
  • Specifications
  • Demo
  • Quote

Advantages

Increased laboratory efficiency
A constant, uninterrupted gas supply of guaranteed purity eliminates interruptions of analyses to change cylinders and reduces the amount of instrument re-calibrations required.

Improved economy
Pure nitrogen gas produced as standard.

Improved safety
Nitrogen produced at low pressure and ambient temperature removes the need for high pressure cylinders.

Security of supply
Integral oil free air compressor as an option guarantees continuous gas supply, independent of in house compressed air supply.

Simple installation
Gas generators can be installed in the laboratory, on or under a bench, eliminating the need for long gas lines from cylinders secured elsewhere.

Characteristics

  • Innovation and unique design: space saving lab bench
  • Fully regenerative PSA technology: reduced risk of gas contamination and phthalate free
  • Generates Nitrogen on demand from external compressed air
  • Designed to run 24 hours a day
  • Minimum maintenance with an annual filter change : no need to open the instrument
  • Alarms for catalyst duration, catalyst temperature, and pressure
  • USB/RS232 ports to remote the system anywhere in the world for diagnostics purpose
  • Low power, low noise, low maintenance
  • Fast purity (10 ppm in less than 3 hours)

Specifications

ModelsT.N2.HP.500T.N2.HP.750
General Information
Flow rate (max)500 cc/min750 cc/min
Nitrogen purity> 99.9995% (< 5 ppm O2 @ 7 bar (101.5 psi) inlet pressure)
O2 content< 5 ppm
N2 pressure6 bar (87 psi)
Hydrocarbon content (CH4 free)
Air Inlet
Air inlet requirementParticulate : < 1 micron
Dewpoint : Between -20°C (-4°F) -40°C (-40°F)
Oil < 0.01 mg/m3
Flow rate (max)15 L/min18 L/min
Min supply pressure7 bar (101.5 psi)
Max supply pressure10 bar (145 psi)
Min temperature1°C (34°F)
Max temperature35°C (95°F)
Communication
LCD displayTouch screen (operating parameters, system status, alarms)
with LED indicators (Power on /off; ready or errors)
RS232/RS485Option
USB/PC control monitoringIn series
General Data
Supply rating110 – 120 V 60 Hz / 220 – 240 V 50 Hz
Installation power (max)20 W
Dimensions (W x H x D)14 x 49 x 63 cm (5.5" x 19" x 25")
CertificationCE, CSA, FCC
Connections
Outlet port1/8" GF female
Inlet port1/8" GF female
Operating conditions
Temperature5 – 35°C (41 – 95°F)
Humidity (max, non condensing)80% at 25°C (77°F)
Noise< 25 dB(A)
IP ratingIP20
Pollution degree rating2 (with no aromatic compounds)